POLARIS LA 60 SERIESpool and spa heaters

POLARIS LA 60 SERIES

PERFECT PERFORMANCE

The Polaris LA 60 Series Air to Water heat pumps enjoy extensive popularity in the global market. With perfect performance at the ambient temperature as low as -25°C, the units can provide efficient heating for your house and sufficient domestic hot water for your family.

  • C.O.P up to 4.2
  • Smooth operation
  • Intensive protections
  • 60°C hot water temperature
  • High efficiency
  • Hydrophilic coated air exchanger
  • EVI compressor
  • Electronic expansion value
  • Stepless speed fan motor

HOT WATER TEMPERATURE UP TO 60°C

C.O.P. UP TO 4.2

The application of EVI technology together with the high efficiency heat exchanger improves the heat exchanging rate and results a COP of up to 4.2.

SMOOTH OPERATION AT AMBIENT TEMP. AS LOW AS - 25°C

Polaris LA 60 Series heat pumps achieve optimum performance at ambient temperature as low as -25°C, resulting stable running all the year round

INTENSIVE PROTECTIONS

Intensive protections have been added to Polaris Series LA 60 Air to Water Heat Pumps in order to ensure that the units operate safely. Protections against high discharging temperature, high vacuum degree, excess current and large temperature differences are reinforced in Polaris Series Heat Pumps excess current and large temperature difference are reinforced in Polaris Series Heat Pumps.

HIGHER WATER TEMP. 60°C

Due to the high outlet water up to 60 °C, the unit can replace the standard boilers in house heating and domestic hot water application.

IMPROVED EFFICIENCY

With the strong counter current design, the patented C&S heat exchanger is conducive to improving the efficiency and reliability of the unit.

AIR EXCHANGER

Air exchanger(fins-coil) with hydrophilic coating is highly stronger anti-corrosive and performs higher efficiency.

EVI COMPRESSOR

The EVI compressor ensures the unit operate safely at low ambient temperature with higher efficiency and less noise.

ELECTRONIC EXPANSION VALVE

The electronic expansion valve is critical to control the volume of the refrigerant accurately and also reduces energy consumption.

STEPLESS SPEED FAN MOTOR

The use of stepless speed fan motor adjusts the fan speed according to different working conditions and broadens the application range of the unit.

MODEL030040050060120
Heating Capacity*kW9.212.014.517.034.4TBC
BTU/h31300410004930057800120000TBC
C.O.P.W/W4.13.84.24.404.41TBC
Heating Capacity**kW9.512.915.017.533.3TBC
BTU/h32300438005100059500110000TBC
C.O.P.W/W2.572.42.62.62.56TBC
Cooling CapacitykW6.27.99.512.525.0TBC
BTU/h21100268003230004250063000TBC
EERW/W2.702.632.712.782.75TBC
Power SupplyV/Ph/Hz230V-/50Hz230V-/50Hz230V-/50Hz380V/3N-/50Hz380V/3N-/50HzTBC
Compressor Number/11112TBC
Compressor/EVI ScrollEVI ScrollEVI ScrollEVI ScrollEVI ScrollTBC
Fan Number/12222TBC
Net Dimensions L/W/Hmm1160/430/8451385/450/11801600/1000/1600TBC
Shipping Dimensions L/W/Hmm1200-480-8801390/500/12101680/1060/1740TBC

*Heating: ambient temp. (DB/WB): 7°C/6°C, water temp. (in/out): 30°C/35°C, **Heating: ambient temp, (DB/WB): 7°C/6°C, water temp, (in/out): 55°C/60°C, Cooling: ambient temp, (DB/WB): 35°C/24°C, water temp, (in/out): 12°C/7°C

...